https://doi.org/10.1140/epjs/s11734-026-02345-4
Regular Article
Non-destructive diagnostics of electric parking brake modules using recurrence analysis of piezoelectric sensor data
1
Faculty of Mathematics and Technical Information Technology, Lublin University of Technology, Nadbystrzycka 38, 20-618, Lublin, Poland
2
Borg Automotive, Metalurgiczna 13B, 20-234, Lublin, Poland
3
Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618, Lublin, Poland
a
This email address is being protected from spambots. You need JavaScript enabled to view it.
Received:
24
October
2025
Accepted:
21
April
2026
Published online:
9
May
2026
Abstract
This paper presents a non-invasive diagnostic approach for Electric Parking Brake (EPB) modules based on recurrence quantification analysis (RQA) of piezoelectric vibration data. Vibration signals were collected from sensors mounted on the motor, planetary gearbox, and pinion under five predefined fault conditions: missing gear in the lower row of the planetary gearbox, missing gear in the upper row, tooth damage in the planetary gear, partially cut timing belt, and incorrect gear installation. Each failure mode was tested repeatedly to obtain statistically reliable datasets for non-linear time-series and recurrence-based analysis. The following RQA quantificators were computed: Determinism (DET), Laminarity (LAM), maximal diagonal line length (
), and mean diagonal line length (L) were calculated to characterize the underlying dynamic behavior. Additional recurrence quantificators describing laminar states—Trapping Time (TT) and maximal vertical line length (
) were used to capture transient stability and synchronization effects. The results show that these RQA quantificators are highly sensitive to mechanical faults, especially within the gearbox, enabling effective fault localization and differentiation between failure types. The missing-gear condition resulted in increased values of DET, LAM, and
, reflecting more regular and structured recurrence patterns, while incorrect pinion installation produced more irregular and weakly correlated responses. Statistical analyses confirmed that the observed differences between fault conditions were significant, not only within experimental groups, but also between individual RQA quantificators, highlighting their diagnostic discriminative capability. The proposed method allows efficient fault detection without disassembling the EPB unit, thus reducing remanufacturing costs and downtime. Overall, the study demonstrates that recurrence-based diagnostics provide a robust and interpretable framework for real-time condition monitoring and fault prediction.
© The Author(s) 2026
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

